Search results for: 'qnixr 5500 paint thickness gauge modular system gauge body with interchangeable probe and cable fe 2'

Set Ascending Direction
View as List Grid

274 items

Page
per page
Related search terms
qnixr 5500 paint thickness gauge modular system gauge body probe probe holder and cable fe nfe 200 200 mils
qnixr 5500 paint thickness gauge modular system gauge body probe probe holder and cable fe 120 mils
qnixr 5500 paint thickness gauge modular system gauge body probe probe holder and cable nfe 120 mils
qnixr 5500 paint thickness gauge modular system gauge body probe probe holder and cable fe nfe 200 120 mils
qnixr 1500 qnix r1200 qnix 1500 coating thickness gauge basic model fe non ferrous 200 mil
  1. QNix® 5500 Fe 120 mils Paint Thickness Gauge | Paint Meter | Dry Film Gauge
    NEW
    QNix® 5500 Fe 120 mils Paint Thickness Gauge | Paint Meter | Dry Film Gauge
    The Automation Dr. Nix QNix® 5500 Dry Film Paint Thickness Gauge with integral probe Fe 120 mils is a rugged – IP protection IP64 and electronic digital Paint thickness gauge designed for fast (more than 120 readings per minute), accurate, reliable and repeatable dry Film thickness measurements on both ferrous and non-ferrous metals. QNix® 5500 paint Depth Thickness Gauge with integral probe Fe 120 mils is ideal for single-handed operations. The proven Hall sensor technology (ISO 2178, ASTM D7091) is used to measure non-conductive, non-magnetic coating thickness on magnetic substrates such as steel, chrome, copper, zinc. The eddy current principle (ISO 2360, ASTM D7091) is used to measure non-conductive coating thickness on non-ferrous metals substrates. With the capability to interchange probes and statistically display, the QNix® 5500 Paint Thickness Gauge with integral probe Fe 120 mils is a cost-effective solution for users who do not need the many added features of a more advanced Paint Thickness Gauge. The probes, which are either integrated or interchangeable with cable, are built with stainless enclosed by a protective membrane IP65 for dust resistant (weatherproof). It features a polished ruby tip that is extremely wear-resistant. The QNix® 5500 Paint Thickness Gauge with integral probe Fe 120 mils comes fully calibrated and is equipped with a running average mode but readings cannot be saved. A Certificate of Calibration traceable to a national metrology institute NIST or PTB is included. Because of the modular probe system –Fe, NFe, Fe/NFe, integrated and cable probe options, and the different measuring ranges, there are up-to 13 gauge combinations available. Learn More
    $650.00
  2. QNix® 5500 integral dual Fe/Nfe 120 mils Paint Thickness Gauge | Paint Meter | Dry Film Gauge
    NEW
    QNix® 5500 integral dual Fe/Nfe 120 mils Paint Thickness Gauge | Paint Meter | Dry Film Gauge
    QNix® 5500 Dry Film Coating Thickness Gauge by Automation Dr. Nix with integral probe dual Fe/Nfe 120 mils is a rugged – IP protection IP64 and electronic digital Paint thickness gauge designed for fast (more than 120 readings per minute), accurate, reliable and repeatable dry Film thickness measurements on both ferrous and non-ferrous metals. QNix® 5500 paint Thickness Gauge with integral probe dual Fe/Nfe 120 mils is ideal for single-handed operations. The proven Hall sensor technology (ISO 2178, ASTM D7091) is used to measure non-conductive, non-magnetic coating thickness on magnetic substrates such as steel, chrome, copper, zinc. The eddy current principle (ISO 2360, ASTM D7091) is used to measure non-conductive coating thickness on non-ferrous metals substrates. With the capability to interchange probes and statistically display, the QNix® 5500 Paint Thickness Gauge with integral probe dual Fe/Nfe 120 mils is a cost-effective solution for users who do not need the many added features of a more advanced Paint Thickness Gauge. The probes, which are either integrated or interchangeable with cable, are built with stainless enclosed by a protective membrane IP65 for dust resistant (weatherproof). It features a polished ruby tip that is extremely wear-resistant. The Automation Dr. Nix QNix® 5500 Paint Thickness Gauge with integral probe dual Fe/Nfe 120 mils comes fully calibrated and is equipped with a running average mode but readings cannot be saved. A Certificate of Calibration traceable to a national metrology institute NIST or PTB is included. Because of the modular probe system –Fe, NFe, Fe/NFe, integrated and cable probe options, and the different measuring ranges, there are up-to 13 gauge combinations available. Learn More
    $880.00
  3. QNix® 5500  Dry Film Thickness Gauge - ext. cable Non Fe 120 mils Paint  Gauge |Automation Dr. Nix
    NEW
    QNix® 5500 Dry Film Thickness Gauge - ext. cable Non Fe 120 mils Paint Gauge |Automation Dr. Nix

    Here is why you should buy Non Ferrous 120 mils:

    Fastest in the market: Measuring speed: Powder Coating Dry Film Thickness Gauge ≥ 120 + readings per minute for fast, time-saving coating thickness inspection.

    Onscreen continuous running (basic) statistics.

    Color LCD, Adjustable display resolution, Flip display 0°, 90°, 180°, 270° automatic or manual.

    Robust, fiber-reinforced 5 piece casing IP class: IP64 –dust and splash water protection; stainless steel probe IP65.

    Awesome R&R Test results.

    Automatic substrate switch: Ferrous (steel) and combo (all metals) (measuring range– 50, 120, or 200 mils).

    Two-year warranty: free first-year factory calibration.

    Certificate of Calibration traceable to a national metrology institute PTB is included.

    Optional with a detachable probe with an extension cable.

     So get yours today.

    Learn More
    $860.00
  4. QNix® 5500  Dry Film Thickness Gauge - ext. cable, Non Fe 200 mils - Automation Dr. Nix
    NEW
    QNix® 5500 Dry Film Thickness Gauge - ext. cable, Non Fe 200 mils - Automation Dr. Nix

    Here is why you should buy QNix 5500 Powder coating dry film thickness gauge modular Nonferrous 200 mils:

    Fastest in the market: Measuring speed: ≥ 120 + readings per minute for fast, time-saving coating thickness inspection.

    Onscreen continuous running (basic) statistics.

    Color LCD, Adjustable display resolution, Flip display 0°, 90°, 180°, 270° automatic or manual.

    Robust, fiber-reinforced 5 piece casing IP class: IP64 –dust and splash water protection; stainless steel probe IP65.

    Awesome R&R Test results.

    Automatic substrate switch: Ferrous (steel) and combo (all metals) (measuring range– 50, 120, or 200 mils).

    Two-year warranty: free first-year factory calibration.

    Certificate of Calibration traceable to a national metrology institute PTB is included.

    Optional with a detachable probe with an extension cable.

     So get yours today.

     

    Learn More
    $965.00
  5. QNix® 7500 Basic int. Dual probe 0- 80 mils Paint Thickness Gauge | Paint Meter | Dry Film Gauge
    • Our QNix® 7500 Paint thickness Meter is part of the product line of non-destructive measurement gauges by Automation Dr. Nix. Designed for the future, this modular system Paint Thickness gauge is characterized by a wide application range and a robust build, already well known from our other gauges. It is possible for example to use the QNix® 7500 with an integrated probe as a one-hand operated gauge, or by using a connecting cable, as a Paint gauge with an external probe. Using the respective probe, the gauge will measure coatings on steel and iron or coatings on a non-magnetic, metallic substrate such as aluminum. Please read these instructions carefully before operating the gauge for the first time. It will help you to make use of all the advantages and conveniences the QNix® 7500 Paint Thickness meter has to offer and measures on both ferrous metal substrates and non-ferrous metal substrates. Would you like to know more about the other coating thick- ness gauges of our product line? Or do you have any questions concerning coating thickness measuring? Please do not hesitate to contact us. Our specialists with their long- standing experience will be glad to assist you. Measurement of non-ferrous or non-ferromagnetic coatings on ferromagnetic substrate all isolating coatings on non-ferrous metals
    • Small, convenient Coating Thickness gauge QNix® 7500
    • Modular measurement system with a wide range of probes
    • Probes can be inserted or used with an adapter cable
    • Angled probe can be used with an adapter cable
    • Measurements on Fe substrate
    • Large measurement range of up to 80 mils
    • The QNix® 7500 complies to national and international (DIN, ISO, BS, ASTM) standards and regulations: DIN 50981, 50984 ISO 2178, 2360, 2808 BS 5411 (3 & 11), 3900-C5 ASTM B499, D 7091

    Scope of delivery of the QNix® 7500

    • QNix® 7500 Gauge Body
    • Measuring probe (optional)
    • Adapter cable for external probe
    • Test certificate for optional measuring probe
    • Fe & NFe reference plate
    • 9 V block battery (alkaline)
    • Operating instructions
    • Robust plastic case for transport and storage
    Learn More
    $965.00
  6. QNix® 5500 Dry Film Thickness Gauge - integral  Fe/Nfe 200/120 mils- Automation Dr. Nix
    NEW
    QNix® 5500 Dry Film Thickness Gauge - integral Fe/Nfe 200/120 mils- Automation Dr. Nix
    QNix® 5500 Powder Coating Dry Film Thickness Gauge by Automation Dr. Nix with integral probe dual Fe/Nfe 200/120 mils is a rugged – IP protection IP64 and electronic digital Paint thickness gauge designed for fast (more than 120 readings per minute), accurate, reliable and repeatable dry Film thickness measurements on both ferrous and non-ferrous metals. QNix® 5500 paint Thickness Gauge with integral probe dual Fe/Nfe 200/120 mils is ideal for single-handed operations. The proven Hall sensor technology (ISO 2178, ASTM D7091) is used to measure non-conductive, non-magnetic coating thickness on magnetic substrates such as steel, chrome, copper, zinc. The eddy current principle (ISO 2360, ASTM D7091) is used to measure non-conductive coating thickness on non-ferrous metals substrates. With the capability to interchange probes and statistically display, the QNix® 5500 Paint Thickness Gauge with integral probe dual Fe/Nfe 200/120 mils is a cost-effective solution for users who do not need the many added features of a more advanced Paint Thickness Gauge. The probes, which are either integrated or interchangeable with cable, are built with stainless enclosed by a protective membrane IP65 for dust resistant (weatherproof). It features a polished ruby tip that is extremely wear-resistant. The Automation Dr. Nix QNix® 5500 Paint Thickness Gauge with integral probe dual Fe/Nfe 200/120 mils comes fully calibrated and is equipped with a running average mode but readings cannot be saved. A Certificate of Calibration traceable to a national metrology institute NIST or PTB is included. Because of the modular probe system –Fe, NFe, Fe/NFe, integrated and cable probe options, and the different measuring ranges, there are up-to 13 gauge combinations available. Learn More
    $960.00
  7. Qnix 7500 Basic int. w/ Dual probe 200 mils Paint Thickness Gauge | Paint Meter | Dry Film Gauge

    QNix® 7500 Paint Thickness gauge offers mobility, simplest operation, highest measuring accuracy for coating thickness measurement. It can measure up to 200 mils on ferrous and nonferrous metals (aluminum, zinc, copper, brass, stainless steel) and unusual application variety. The small probe allows for better placement on the measuring surface, even on minimum curvatures of 3mm for convex and 30mm for concave.  As a really small and handy gauge, QNix® 7500 can be used either with a directly inserted miniature measuring probe or with a measuring probe alongside an adaptor cable for non-destructive measurements of coating thickness on all Fe- and NFe-substrates. Simply place the probe head on the coated surface and read. Check the accuracy of your QNix 7500 with QNix Coating thickness certified shims / standards. This Thickness gauge combination uses two measuring principles: The Magnetic flux also known as Hall effect principle and the Eddy current principle. It conforms with DIN EN ISO 2808, DIN 50981, DIN 50984, ISO 2178, BS 5411 (3 & 11), BS 3900 - C5, ASTM B 499, ISO 2360, ASTM D 1400, ASTM D 1186, ASTM D 7091

    QNix 7500 Coating Thickness  w/ 5 mm Advantages:

    • Small, convenient Coating Thickness gauge, DFT QNix® 7500
    • Modular measurement system with a wide range of probes
    • Probes can be inserted or used with an adapter cable
    • The angled probe can be used with an adapter cable
    • Measurements on Fe & NFe substrates
    • Large measurement range of up to 200 mils
    • The QNix® 7500 complies to national and international (DIN, ISO, BS, ASTM) standards and regulations: DIN 50981, 50984 ISO 2178, 2360, 2808 BS 5411 (3 & 11), 3900-C5 ASTM B499, D 7091

    Scope of delivery of the QNix® 7500

    • QNix® 7500 Gauge Body
    • Measuring probe (optional)
    • Adapter cable for external probe (optional)
    • Test certificate for optional measuring probe
    • Fe & NFe reference plates
    • 9 V block battery (alkaline)
    • Extension Cable
    • Operating instructions
    • Robust plastic case for transport and storage
    Learn More
    $1,000.00
  8. QNix® 7500 Basic int. NFe probe 80 mils Paint Thickness Gauge | Paint Meter | Dry Film Gauge
    • Small, convenient Coating Thickness gauge QNix® 7500
    • Modular measurement system with a wide range of probes
    • Probes can be inserted or used with an adapter cable
    • Angled probe can be used with an adapter cable
    • Measurements on NFe substrate
    • Large measurement range of up to 80 mils
    • The QNix® 7500 complies to national and international (DIN, ISO, BS, ASTM) standards and regulations: DIN 50981, 50984 ISO 2178, 2360, 2808 BS 5411 (3 & 11), 3900-C5 ASTM B499, D 7091

    Scope of delivery of the QNix® 7500

    • QNix® 7500 Gauge Body
    • Measuring probe (optional)
    • Adapter cable for external probe (optional)
    • Test certificate for optional measuring probe
    • NFe reference plate
    • 9 V block battery (alkaline)
    • Operating instructions
    • Robust plastic case for transport and storage
    Learn More
    $850.00
  9. QNix 7500 Basic w/ Fe probe 0- 200 mils Ext. Cable Paint Thickness Gauge | Paint Meter | Dry Film Gauge
    • Small, convenient Coating Thickness gauge QNix® 7500
    • Modular measurement system with a wide range of probes
    • Probes can be inserted or used with an adapter cable
    • Angled probe can be used with an adapter cable
    • Measurements on Fe substrates
    • Large measurement range of up to 200 mils
    • The QNix® 7500 Fe 200 mils probe complies to national and international (DIN, ISO, BS, ASTM) standards and regulations: DIN 50981, 50984 ISO 2178, 2360, 2808 BS 5411 (3 & 11), 3900-C5 ASTM B499, D 7091

    Scope of delivery of the QNix® 7500

    • QNix® 7500 Gauge Body
    • Measuring probe (optional)
    • Adapter cable for external probe (optional)
    • Test certificate for optional measuring probe
    • Fe reference plate
    • 9 V block battery (alkaline)
    • Operating instructions
    • Robust plastic case for transport and storage
    Learn More
    $1,045.00
  10. QNix® 7500 Basic - NFe probe 200 mils & Ext. Cable Paint Thickness Gauge | Paint Meter | Dry Film Gauge
    • Small, convenient Coating Thickness gauge QNix® 7500
    • Modular measurement system with a wide range of probes
    • Probes can be inserted or used with an adapter cable
    • Angled probe can be used with an adapter cable
    • Measurements on Fe  substrates
    • Large measurement range of up to 200 mils
    • The QNix® 7500 complies to national and international (DIN, ISO, BS, ASTM) standards and regulations: DIN 50981, 50984 ISO 2178, 2360, 2808 BS 5411 (3 & 11), 3900-C5 ASTM B499, D 7091

    Scope of delivery of the QNix® 7500

    • QNix® 7500 Gauge Body
    • Measuring probe (optional)
    • Adapter cable for external probe
    • Test certificate for optional measuring probe
    • NFe reference plate
    • 9 V block battery (alkaline)
    • Operating instructions
    • Robust plastic case for transport and storage
    Learn More
    $1,070.00
Set Ascending Direction
View as List Grid

274 items

Page
per page