<img src="/>

QNix® 7500 Basic int. Dual probe 0- 80 mils Paint Thickness Gauge | Paint Meter | Dry Film Gauge

Paint Thickness Gauge QNix® 7500 Basic - w/NFe probe 0- 80 mils by Automation Dr. Nix

QNix® 7500 Basic int. NFe probe 80 mils Paint Thickness Gauge | Paint Meter | Dry Film Gauge

QNix Quanix 7500 paint thickness mil gauge

QNix® 7500 Basic -Fe 80 mils & Ext. Cable Paint Thickness Gauge | Paint Meter | Dry Film Gauge

QNix® 7500 Basic int. Dual probe 0- 80 mils Paint Thickness Gauge | Paint Meter | Dry Film Gauge

  • Our QNix® 7500 Paint thickness Meter is part of the product line of non-destructive measurement gauges by Automation Dr. Nix. Designed for the future, this modular system Paint Thickness gauge is characterized by a wide application range and a robust build, already well known from our other gauges. It is possible for example to use the QNix® 7500 with an integrated probe as a one-hand operated gauge, or by using a connecting cable, as a Paint gauge with an external probe. Using the respective probe, the gauge will measure coatings on steel and iron or coatings on a non-magnetic, metallic substrate such as aluminum. Please read these instructions carefully before operating the gauge for the first time. It will help you to make use of all the advantages and conveniences the QNix® 7500 Paint Thickness meter has to offer and measures on both ferrous metal substrates and non-ferrous metal substrates. Would you like to know more about the other coating thick- ness gauges of our product line? Or do you have any questions concerning coating thickness measuring? Please do not hesitate to contact us. Our specialists with their long- standing experience will be glad to assist you. Measurement of non-ferrous or non-ferromagnetic coatings on ferromagnetic substrate all isolating coatings on non-ferrous metals
  • Small, convenient Coating Thickness gauge QNix® 7500
  • Modular measurement system with a wide range of probes
  • Probes can be inserted or used with an adapter cable
  • Angled probe can be used with an adapter cable
  • Measurements on Fe substrate
  • Large measurement range of up to 80 mils
  • The QNix® 7500 complies to national and international (DIN, ISO, BS, ASTM) standards and regulations: DIN 50981, 50984 ISO 2178, 2360, 2808 BS 5411 (3 & 11), 3900-C5 ASTM B499, D 7091

Scope of delivery of the QNix® 7500

  • QNix® 7500 Gauge Body
  • Measuring probe (optional)
  • Adapter cable for external probe
  • Test certificate for optional measuring probe
  • Fe & NFe reference plate
  • 9 V block battery (alkaline)
  • Operating instructions
  • Robust plastic case for transport and storage
$965.00
Availability: In stock
SKU
T1453009
Automation Dr. Nix QNix® 7500 Paint thickness gauge is part of the product line of non-destructive measurement gauges. Designed for the future, this modular system gauge is characterized by a wide application range and a robust build, already well known from our other gauges. It is possible for example to use the QNix® 7500 Paint Gauge with an integrated probe as a one-hand operated gauge, or by using a connecting cable, as a gauge with an external probe. Using the respective probe, the gauge will measure coatings on steel and iron or coatings on a non-magnetic, metallic substrate such as aluminum. Please read these instructions carefully before operating the gauge for the first time. It will help you to make use of all the advantages and conveniences the QNix® 7500 has to offer. Would you like to know more about the other coating thickness gauges of our product line? Or do you have any questions concerning coating thickness measuring? Please do not hesitate to contact us. Our specialists with their long-standing experience will be glad to assist you. QNix® 7500 Paint thickness measuring gauge is a combination gauge with a wide range of applications. Optionally, it is available with memory and statistical functions (QNix® 7500 with Memory capacity Paint Thickness Gauge). The basic gauge can be combined with an integrated Fe-, NFe- or dual-probe. If the gauge shall be used with an external probe, just pull the probe out of the gauge and connect the probe with the optionally available adapter cable. The Fe-probe measures all non-magnetic coatings such as lacquer, powder coatings, plastic, enamel, chromium, copper, zinc, etc. on steel or iron. The Non-ferrous probe measures all insulating coatings such as lacquer, plastic, enamel, etc. on non-magnetic substrates such as aluminum, copper, brass or stainless steel. With the integrated interface, readings can be transferred online to a computer (serial-port or USB-port). The QNix® 7500 M coating thickness measuring gauge can be supplied with memory to store readings and even subdivide them into blocks. Up to 3900 readings can be stored. As a further option, an evaluation software for statistical evaluation and documentation can be supplied. The QNix® 7500 complies to national and international (DIN, ISO, BS, ASTM) standards and regulations: DIN 50981, 50984 ISO 2178, 2360, 2808 BS 5411 (3 & 11), 3900-C5 ASTM B499, D 7091 QNix® 7500 incorporates the latest electronic technology in order to fulfill different measuring tasks. This high precision instrument covers a wide range of applications, yet it is robust and easy-to-use in every-day practice. If operated and treated with care, it will serve you many years producing accurate and reliable readings. Do not let it drop and protect it from dirt, dust and other substances. Protect the gauge from moisture, chemically aggressive substances and/or gases. After use, the gauge should be stored in its protective carrying case. Substantial changes in temperature can influence the readings, as is the case with all precision gauges. Do not expose the gauge to strong, direct sunlight or to other sources of energy causing temperature shocks. The housing is resistant to most solvents. However, resistance against all chemical substances cannot be guaranteed. Use only a damp, soft cloth to clean the housing. Accurate readings can only be obtained, if the measuring probe is clean. Check the probe regularly and remove residues such as lacquer etc. from the ruby tip. If the gauge will not be used for a longer period, remove the

QNix® 7500 offers a lot of mobility, simplest operation, highest measuring accuracy up to 5000 µm and unusual application variety. As a really small and handy gauge, QNix® 7500 can be used either with a directly inserted miniature measuring probe or with a measuring probe alongside an adaptor cable for non-destructive measurements of coating thickness on all Fe- and NFe-substrates. Place and read

With a simple exchange of the probe, QNix® 7500 can be optimally adapted to suit the measuring task. For these tasks, there is a comprehensive probe program available. Probe change occurs via simple pull out and insert. You can immediately start using the gauge again.

More Information
Country of ManufactureGermany
Write Your Own Review
You're reviewing:QNix® 7500 Basic int. Dual probe 0- 80 mils Paint Thickness Gauge | Paint Meter | Dry Film Gauge
Your Rating